Wieser HP, Huang Y, Schauer J, Lascaud J, Wuerl M, Lehrack S, Radonic D, Vidal M, Herault J, Chmyrov A, Ntziachristos , Assmann W, Parodi K, Dollinger G (2021)
Publication Type: Journal article
Publication year: 2021
Book Volume: 66
Article Number: 245020
Journal Issue: 24
Accurate knowledge of the exact stopping location of ions inside the patient would allow full exploitation of their ballistic properties for patient treatment. The localized energy deposition of a pulsed particle beam induces a rapid temperature increase of the irradiated volume and leads to the emission of ionoacoustic (IA) waves. Detecting the time-of-flight (ToF) of the IA wave allows inferring information on the Bragg peak location and can henceforth be used for in-vivo range verification. A challenge for IA is the poor signal-to-noise ratio at clinically relevant doses and viable machines. We present a frequency-based measurement technique, labeled as ionoacoustic tandem phase detection (iTPD) utilizing lock-in amplifiers. The phase shift of the IA signal to a reference signal is measured to derive the ToF. Experimental IA measurements with a 3.5 MHz lead zirconate titanate (PZT) transducer and lock-in amplifiers were performed in water using 22 MeV proton bursts. A digital iTPD was performed in-silico at clinical dose levels on experimental data obtained from a clinical facility and secondly, on simulations emulating a heterogeneous geometry. For the experimental setup using 22 MeV protons, a localization accuracy and precision obtained through iTPD deviates from a time-based reference analysis by less than 15 μm. Several methodological aspects were investigated experimentally in systematic manner. Lastly, iTPD was evaluated in-silico for clinical beam energies indicating that iTPD is in reach of sub-mm accuracy for fractionated doses < 5 Gy. iTPD can be used to accurately measure the ToF of IA signals online via its phase shift in frequency domain. An application of iTPD to the clinical scenario using a single pulsed beam is feasible but requires further development to reach <1 Gy detection capabilities.
APA:
Wieser, H.P., Huang, Y., Schauer, J., Lascaud, J., Wuerl, M., Lehrack, S.,... Dollinger, G. (2021). Experimental demonstration of accurate Bragg peak localization with ionoacoustic tandem phase detection (iTPD). Physics in Medicine and Biology, 66(24). https://dx.doi.org/10.1088/1361-6560/ac3ead
MLA:
Wieser, H. P., et al. "Experimental demonstration of accurate Bragg peak localization with ionoacoustic tandem phase detection (iTPD)." Physics in Medicine and Biology 66.24 (2021).
BibTeX: Download