Automatic phase point determination of minimal motion reconstruction intervals with motion maps in ECG-gated CT diagnostics of coronary sclerosis Die automatisierte Bestimmung eines optimalen Rekonstruktionsintervalls bei der nativen EKG-gegateten CT-Diagnostik der Koronarsklerose mittels "Motion Maps".

Klink T, Hoffmann MH, van Stevendaal U, Regier M, Adam G, Grass M, Begemann PG (2009)


Publication Type: Journal article

Publication year: 2009

Journal

Book Volume: 181

Pages Range: 675-682

Journal Issue: 7

DOI: 10.1055/s-0028-1109362

Abstract

PURPOSE: Cardio-CT motion maps for automated cardiac phase point determination were evaluated for image quality and reliability of coronary calcium scores. MATERIALS AND METHODS: 24 patients underwent ECG-gated non-enhanced cardiac CT for calcium scoring. From raw data the motion map software reconstructed low-resolution images in 2 % steps of the RR interval and automatically generated cardiac motion maps for determination of minimal motion phase points. Diagnostic images were reconstructed in 10% steps of the RR interval (RR data) and according to the motion maps (MM data). For every data set, the Agatston score was calculated. Image quality was evaluated by two independent observers. Image quality was correlated with the Agatston score. RESULTS: The Agatston score calculated over the RR interval showed a mean variation of 127 with 41% of patients assigned to more than one risk group. If the motion map RR intervals were calculated, only 16% patients were assigned to different risk categories with a mean variation of 55. Regarding the image quality, the inter-rater variance was moderate. The best image quality was achieved with the 30 - 40% and 70 - 80% RR interval. Over the complete RR interval motion map reconstructions produced a good image quality. CONCLUSION: Calculation of the Agatston score requires selection of the proper reconstruction interval to guarantee the assignment of patients into the appropriate risk category. By using motion maps for phase point determination, the amount of necessary reconstruction can be minimized and the assignment to different risk groups is also reduced.

Involved external institutions

How to cite

APA:

Klink, T., Hoffmann, M.H., van Stevendaal, U., Regier, M., Adam, G., Grass, M., & Begemann, P.G. (2009). Automatic phase point determination of minimal motion reconstruction intervals with motion maps in ECG-gated CT diagnostics of coronary sclerosis Die automatisierte Bestimmung eines optimalen Rekonstruktionsintervalls bei der nativen EKG-gegateten CT-Diagnostik der Koronarsklerose mittels "Motion Maps". Röfo: Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 181(7), 675-682. https://doi.org/10.1055/s-0028-1109362

MLA:

Klink, T., et al. "Automatic phase point determination of minimal motion reconstruction intervals with motion maps in ECG-gated CT diagnostics of coronary sclerosis Die automatisierte Bestimmung eines optimalen Rekonstruktionsintervalls bei der nativen EKG-gegateten CT-Diagnostik der Koronarsklerose mittels "Motion Maps"." Röfo: Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 181.7 (2009): 675-682.

BibTeX: Download